Steadfast, real-time precision measurement
even in the most demanding industrial sites
A non-contact optical TDLAS analyzer
reads emission gas concentrations within 1 second.
Install and connect,
and measurement begins right away
"Right on-site, with no need to extract the gas"
iSensIRs' emission gas monitoring sensor for environmental and industrial use is a non-contact (in-situ) optical TDLAS analyzer that does not directly sample the gas. There is no need for a separate sampling device or demanding maintenance. Simply connect the power, data, and purge gas, and it starts operating immediately—boosting process operation efficiency without complex preparation.
-
Easy Installation
Installation is nothing more than connecting the power and piping. It can start operating right away, with no special preparation.
-
On-Site Measurement
It measures the gas directly at the piping or stack site. Since there is no separate sampling process, no loss or delay occurs.
-
Instant Response
Changes in emission gases are detected within 1 second. The moment an anomaly appears, it immediately feeds into process control.
The Core Value for Customers
Customer ValueEasy Adoption
There are no complex procedures. You can install it and start operating as soon as you receive it, so the time to deployment is short.
Cost Savings
No gas extraction equipment is required and maintenance is simple. You can save on operating costs over the long term.
High Stability
There is no zero drift, and calibration holds for a long time. That means you obtain measurements you can trust over extended periods.
iSensIRs' Distinctive Key Features
Key FeaturesUltra-Fast Real-Time Monitoring
Response speed is within 1 second. It captures even the momentary movements of emission gases without missing a thing.
Direct In-Situ Measurement
It is a non-contact method that measures directly on-site without sampling the gas. There is no loss or delay arising from the measurement process.
Blocking Background Gas Interference
iSensIRs' proprietary AI algorithm filters out interference from background gases. Thanks to this, it accurately analyzes only the target gas you want to measure.
Stable Measurement Even in Extreme Environments
From high and low temperatures and heavy dust to corrosive gases such as ammonia and methane—the measurements stay steady even amid the harshest conditions.
Flexible Scalability
It supports both long-distance optical paths and a built-in calibration check option. It adapts flexibly even as the installation environment and operating conditions change.
Product Specifications
Specifications
- Analysis Technology TDLAS, with proprietary AI algorithm
- Target Gases Supports multi-gas measurement including ammonia and methane
- Response Time Within 1 second (real-time)
- Limit of Detection (LOD) 1 ppm or less
- Sensor Type Fixed-mount gas sensor
- Gas Sampling Not required (non-contact)
Inquiries & Consultation
If you have questions about adopting the product or applying it on-site, please feel free to contact us anytime.